By Brands

Brands

  • Filter
Category: FOTRIC - USA

  Fotric 226B Thermal Imaging System for Fever Screening The FOTRIC 226B Thermal Imaging Fever Screening system offers an automated and precise setup, built for instantaneous fever screening with software automation and without disrupting the flow of foot traffic. With a temperature range of 20˚C to 60˚C (68˚F - 140˚F), the FOTRIC 226B has a high level of precision with a 384 x 288 thermal resolution (110K pixels) and accuracy calibrated at ±0.2ºC. The non-contact measurement type of the 226B ensures the continuing safety of the detection personnel by keeping them a safe distance from potential infection. Both audible and visual indication is given through a voice alarm and an on-screen red-box appearing if an abnormal body temperature is caught. Using inbuilt AI, the FOTRIC 226B is a Polysilicon-FPA detector producing up to 110K temperature measuring points per photo. Issued with a calibration certificate from the Shanghai Institute of Quality Supervision and Inspection Technology, the device is so thorough these measuring points even cover a full head of hair. Compact and IP40 rated, this full body scanner is cost effective, safe and extremely easy to...

DC voltage measurement to verify 24 V power supplies or voltage I/O signals Source DC voltage to test input devices that accept a 1 to 5 volt or 0 to 10 volt signal Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp Output mA signal enables a logging DMM or other device to record the 4 to 20 mA signal without breaking the loop mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal Apply a mA input signal to a device and measure its 4 to 20 mA output on devices such as valves or mA isolators Voltage output linear ramp or 25% step output Automatically change the voltage output for remote testing

Measure 4 to 20 mA signals without ”breaking the loop” just like the innovative and popular Fluke 771 Process Milliamp Clamp meter Source 4 to 20 mA signals for testing control system I/O or I/Ps Simulate 4 to 20 mA signals for testing control system I/O Measure 4 to 20 mA signals with in-circuit measurement Simultaneously measure mA in-circuit with 24 V loop power for powering and testing transmitters Source mA output signals in a linear ramp or 25 % step output– Automatically change the 4 to 20 mA output for remote testing Power saving features, auto-off, backlight timeout extend battery life

Measure mA signals for PLC and control system analog I/O Measure 4 to 20 mA output signals from transmitters without breaking the loop Best in class 0.2 % accuracy Resolution and sensitivity to 0.01 mA Hold function captures and displays changing measurements Dual backlit display with both mA measurement and percent of 4 to 20 mA span Measurement Spotlight illuminates hard to see wires in dark enclosures Detachable clamp with extension cable for measurements in tight locations Measure 10 to 50 mA signals in older control systems using the 99.9 mA range Automatic power off after 15 minutes and 2 minute automatic off for backlight and spotlight

Designed for HVAC applications with capacitance, DC Current (µA), and temperature measurements Small body and jaws fit perfectly in your hand and into tight places Handy 'Display Hold' button keeps measurements on the display Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch) Large, backlit display (on most models) is easy-to-see Auto shut-off maximizes battery life so the meter works when you need it Three year warranty

AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems Troubleshoot harmonics: Analyze and log harmonics digitally or graphically Inrush current: Capture and analyze nuisance tripping, from 3 seconds to 300 seconds Easy to use: Easily confirm power meter setup with large backlit color display of waveforms and trends 3-Phase power: Built in capability for balanced loads View graphs and generate reports: Use power analyzer with included Power Log software

Measurement of leakage current with 3 mA range and 1 µA of resolution, for accurate monitoring of insulation erosion Broad range of measurement, from 1 µA up to 60 A, for all installation needs Advanced shielding to ensure accurate results when measuring near other conductors The high durability clamp construction can withstand over 50,000 operations - added ruggedness that extends the life of your clamp Easy-to-carry, pocket-sized clamp with wide 40 mm (1.5 in) jaw size Handy "Display-Hold" button for capturing readings in hard- to-reach places Auto power-off, with warning buzzer, saves battery life Conformance to IEC1010 and EMC standard for confident measurements Meets all of the applications and performance classes in safety standard VDE0404-4 and VDE0702 for leakage current and differential current measurement of electrical appliances

1000 A AC/DC current measurement with fixed jaw 2500 A AC current measurement with iFlex flexible current probe 1000 V ac and dc voltage measurement True-RMS AC voltage and current for accurate measurements on non-linear signals Frequency measurement to 500 Hz with both jaw and iFlex 60 kΩ resistance measurement with continuity detection Min, max, average and inrush recording to capture variations automatically Wireless technology allows the display to be carried up to 30 ft away from the point of measurement for added flexibility without interference with measurement accuracy iFlex flexible current probe expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access CAT IV 600V, CAT III 1000 V safety rating Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it Ergonomic design fits in your hand and can be used while wearing personal protective...