• Filter

Precise measurement of temperature, humidity and pressure All important values at a glance: current measurement values as well as date and time Calibration and adjustment of the measuring instrument possible on site with the optional calibration and adjustment software Adjustable calibration reminder function

Hanging and standing bracket allows felxible positioning on a wall or desktop Analysis of past temperature and humidity values directly on site without evaluation on a PC All important values at a glance: current and past temperature and humidity values as well as date and time

The accurate TST0189/190 alarm hygrometer reliably indicates when humidity and temperature limits have been exceeded, for example in garden centres, warehouses, cleanrooms, museums, laboratories etc. All the benefits of TST0189 High accuracy ±2 %RH (TST0190) TST0190 with LED alarm, warns if limits are exceeded Storage temperature -40 to +70 °C Operating temperature -10 to +70 °C Battery type 9V block battery Battery life 8736 h Weight 168 g Material/Housing ABS   Probe type NTC Meas. range -10 to +70 °C Resolution 0.1 °C Probe type humid. sensor, cap. Meas. Range +2 to +98 %RH Resolution 0.1 %RH

Complete environmental monitor and alarm  - Wall-Mounted LED type, easy reading  - Alarm set for Hi and Low limit-Temperature and Humidity  - Data Logging Capacity 30,000 records - LED displays real time data  - USB interface- XL Display: 260 x 178 x 47mm- High Accuracy and high sensitivity  

    Storage temperature -30 to +70 °C Operating temperature -20 to +50 °C Battery type Alkali manganese, mignon, Type AA Battery life 200 h Weight 428 g Dimensions 220 x 74 x 46 mm Material/Housing ABS/TPE/Metal Probe - Typ T (Cu-CuNi) Meas. range -200 to +400 °C Accuracy ±0.3 °C (-60 to +60 °C) ±0.5% of mv (remaining range) Resolution 0.1 °C Probe - NTC Meas. range -40 to +150 °C Accuracy ±0.2 °C (-25 to +74.9 °C) ±0.4 °C (-40 to -25.1 °C) ±0.4 °C (+75 to +99.9 °C) ±0.5% of mv (remaining range) Resolution 0.1 °C Probe type Type K Meas. Range -200 to +1370 °C Accuracy ±0.3 °C (-60 to +60 °C) ±(0.2 °C + 0.3% of mv) (remaining range) Resolution 0.1 °C Probe type Absolute pressure probe Meas. Range 0 to 2000 hPa Resolution 0.1 hPa Probe type humid. sensor, cap. Meas. Range 0 to +100 %RH Resolution 0.1 %RH

humidity/temperature instrument, incl. plug-in humidity probe head, battery and calibration document Displays temperature and relative humidity / wet bulb temperature / dewpoint Max./min. values Hold button to freeze readings Display light

* Triple LCD Display for RH% Humidity, T1 for Air Temperature and T2 Type K Thermometer (-200 ℃ ~ 1333 ℃ ). * Dew Point Reading. * Max / Min / Data Hold. * Real Time Stamp. * Periodically Print out from Pre-Set time Interval. Measuring Range T1 : Temperature : - 20 ℃ ~ 60 ℃ (- 4 ℉ ~ 140 ℉ ) Humidity : 10%RH ~ 95%RH T2 : Type K : - 200 ~ 1333 ℃ (- 58 ~ 2431 ℉ ) Resolution 0.1 ℃ /0.1 ℉ /0.1%RH Accuracy T1 : Temperature : +/- 0.8 ℃ , +/- 1.5 ℉ Humidity : +/- 3%RH (at 25 o C, 30….95%RH) T2 : Type K : - 50 ℃ ~ 500 ℃ , +/- (0.1%rdg + 0.8 ℃ ) 500 ℃ ~ 1333 ℃ , +/- (0.2%rdg + 1.8 ℃ ) Input Protection 60V DC or 24 Vrms AC maximum input voltage on any Combination of input Connector. Sampling Rate 1 time/sec Operating Conditions 0 ℃ ~ 40 ℃ (32 o F ~ 104 ℉ ) 10 ~ 80% R.H. Power Source 6 pcs size AAA Alkaline Battery or 9V DC adaptor/500mA minimum. Battery Life Approx. 30 hours. ( interval printing = 60 minute, not including beeper). 70 hours ( except printing & beeper). Size 193(L) x 74(W) x 37(H)mm Weight Approx. 385g Accessories 1. Carrying case, Instruction manual,...

Laboratory Quality Control Air-Conditioning Process Engineering Range: Humidity 10% to 95% R.H. Temperature -20 ℃ to +60 ℃ ; -4 o F to +140 ℉ Resolution 0.1% R.H. 0.1 ℃ , 0.1 ℉ Accuracy (after calibration) Humidity +/ - 3% R.H. (at 25 ℃ , 30...95% R.H.) Temperature +/ - 0.8 ℃ , +/ - 1.5 ℉ Response time Humidity 45% R.H. --> 95% R.H. < = 3min 95% R.H. --> 45% R.H. < =5min Temperature 1 ℃ /2 sec Accessories Carrying case, Instruction manual, Battery. Auxiliary outputs Humidity 10mV DC/1% R.H. Temperature 10mV DC/1 o C, 10mV DC/1 o F Operating / Storage Condition 0 ℃ to 50 ℃< 80% R.H. -10 ℃ to 60 ℃< 70% R.H. Power Source 10mV DC/1 ℃ , 10mV DC/1 ℉ Size 270mm(L)x68mm(W)x25mm(H) Weight 200g Accessories Instruction Manual, Battery and Carrying Case