Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Category: Clamp meters

CAT III 600V 3-1/2 digit LCD with Analog Bargraph. Display Counts: 2000. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, ACA, DCV, Resistance, Diode, Continuity. Maximum conductor size 30mm. Continuity test below 25 ohms, buzzer will sound. Auto Power off. Double injection outer case.

Category: Clamp meters

CAT III 600V 3-1/2 digit LCD with Analog Bargraph. Display Counts: 2000. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, DCA, ACA, DCV, Resistance, Diode, Continuity. Maximum conductor size 30mm. Continuity test below 25 ohms, buzzer will sound. Auto Power off. Double injection outer case.

Category: Clamp meters

CAT IV 600V, CAT III 1000V LCD backlit display, with maximum reading of 6600. AC voltage range: 0 to 750V. AC current range: 0 to 660A. DC voltage range: 0 to 1000V. DC Current: 0 to 660A. Resistance measurement to 66 megohms. Data Hold, Min/Max, Autoranging, DCA Zero. Test Ranges: ACV, ACA, Resistance, Frequency, Diode, Continuity. Work light. Auto Power Off. Double Injection outer case.

Category: Clamp meters

CAT III 600V 3-3/4 digit LCD Backlit Display, with Analog Bargraph. Display Counts: 4000. Auto Ranging. AC/DC current: 0.1µA to 4000µA. (using test leads). AC current: 0.01A to 400A (using jaw measurement). Ranges: ACV, ACA, DCV, DCA, Resistance, Continuity, Capacitance, and Temperature. Maximum conductor size 30mm. Continuity test below 40 ohms, buzzer will sound. Auto Power off. Double injection outer case.

Category: Clamp meters

CAT III 600V Maximum conductor size 30mm. Display counts: 4000. Measures: ACV, DCV, ACA. Measures Phase Sequence. Voltage/Current Harmonics to 25th with THD. W3ø, HV, HA, Phase SEQ, Audible continuity tests. Frequency to 400Hz. Active, Reactive, Apparent power/ energy on. Power Factor, cosø on Single/Three phase systems. Phase sequence.

Category: Clamp meters

● Pocket size. ● 4000 counts. ● Full automatic measurement.    Voltage measurement.    Current measurement.    Resistor measurement. ● Data hold function. ● Continuity check. ● Diode measurement. ● Select function. ● Low battery indication. ● Auto off function. ● Flashlight (Auto off in 1 minute).

Category: Clamp meters

  Product Description CAT III 600V AC/DC current ranges 40A and 400A. Maximum conductor size 30mm. Low battery indication.